“No Cell Power” on a Pro Logic, Aqua Logic or Aqua Rite PRO
The “No Cell Power” message (or “No Cell Power 1” or “2”) means the board no longer sends power to the cell. Check the fuse first: it’s quick.
Applies to: Aqua Rite PRO (the rectangular model), Pro Logic, Aqua Logic / Aqua Plus, OmniLogic and OmniPL.
Pro Logic, Aqua Logic and Aqua Rite PRO
- Turn the power off at the breaker.
- Check the yellow 20 A fuse on the main board.
- It’s blown: replace it with the same type. If the message comes back or the fuse blows again, the main board needs a repair.
- It’s good: the main board needs a repair.
OmniLogic and OmniPL
On the Omni, “No Cell Power” comes from the main board: it needs a repair.
To remove the board: video for the Pro Logic and Aqua Logic. Not sure? Open the troubleshooting guide.
Does your board need a repair?
We repair original Hayward boards within 1 to 2 business days after we receive them, with a 1-year warranty. By mail (Canada, USA and other countries) or by appointment in Mont-Saint-Hilaire, Quebec.